Install Guide

Table Of Contents
QSFP 52 TX2 Bias Current = 0.000mA
QSFP 52 TX3 Bias Current = 0.000mA
QSFP 52 TX4 Bias Current = 0.000mA
QSFP 52 RX1 Power = 0.000mW
QSFP 52 RX2 Power = 0.000mW
QSFP 52 RX3 Power = 0.000mW
QSFP 52 RX4 Power = 0.000mW
DellEMC#show interfaces twentyFiveGigE 1/26 transceiver
QSFP 26/1 Serial ID Base Fields
QSFP 26/1 Id = 0x0d
QSFP 26/1 Ext Id = 0x00
QSFP 26/1 Connector = 0x23
QSFP 26/1 Transceiver Code = 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x00
QSFP 26/1 Encoding = 0x00
QSFP 26/1 Length(SFM) Km = 0x00
QSFP 26/1 Length(OM3) 2m = 0x00
QSFP 26/1 Length(OM2) 1m = 0x00
QSFP 26/1 Length(OM1) 1m = 0x00
QSFP 26/1 Length(Copper) 1m = 0x01
QSFP 26/1 Vendor Rev = A
QSFP 26/1 Laser Wavelength = 38.65 nm
QSFP 26/1 CheckCodeBase = 0x0d
QSFP 26/1 Serial ID Extended Fields
QSFP 26/1 BR max = 0
QSFP 26/1 BR min = 0
QSFP 26/1 Vendor SN = APF12380010GME
QSFP 26/1 Datecode = 120925
QSFP 26/1 CheckCodeExt = 0xf2
[output truncated]
Recognize an Overtemperature Condition
An overtemperature condition occurs, for one of two reasons: the card genuinely is too hot or a sensor has malfunctioned.
Inspect cards adjacent to the one reporting the condition to discover the cause.
If directly adjacent cards are not normal temperature, suspect a genuine overheating condition.
If directly adjacent cards are normal temperature, suspect a faulty sensor.
When the system detects a genuine over-temperature condition, it powers off the card. To recognize this condition, look for the
following system messages:
CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high (temperature reaches or
exceeds threshold of
[value]C)
CHMGR-2-TEMP_SHUTDOWN_WARN: WARNING! temperature is [value]C; approaching shutdown
threshold of [value]C
To view the programmed alarm thresholds levels, including the shutdown value, use the show alarms threshold command.
Example of the show alarms threshold Command
DellEMC#show alarms threshold
-- Temperature Limits (deg C) --
----------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
Unit2 55 60 75 80 85
----------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
Unit3 55 60 75 80 85
1030
Debugging and Diagnostics