● Enable environmental monitoring.
enable optic-info-update interval
DellEMC#show interfaces tengigabitethernet 1/1/2/1 transceiver
QSFP 1/2/1 Serial ID Base Fields
QSFP 1/2/1 Id = 0x0d
QSFP 1/2/1 Ext Id = 0x00
QSFP 1/2/1 Connector = 0x23
QSFP 1/2/1 Transceiver Code = 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x00
QSFP 1/2/1 Encoding = 0x00
QSFP 1/2/1 Length(SFM) Km = 0x00
QSFP 1/2/1 Length(OM3) 2m = 0x00
QSFP 1/2/1 Length(OM2) 1m = 0x00
QSFP 1/2/1 Length(OM1) 1m = 0x00
QSFP 1/2/1 Length(Copper) 1m = 0x01
QSFP 1/2/1 Vendor Rev = A
QSFP 1/2/1 Laser Wavelength = 38.65 nm
QSFP 1/2/1 CheckCodeBase = 0x0d
QSFP 1/2/1 Serial ID Extended Fields
QSFP 1/2/1 BR max = 0
QSFP 1/2/1 BR min = 0
QSFP 1/2/1 Vendor SN = APF12380010GME
QSFP 1/2/1 Datecode = 120925
QSFP 1/2/1 CheckCodeExt = 0xf2
[output truncated]
Recognize an Overtemperature Condition
An overtemperature condition occurs, for one of two reasons: the card genuinely is too hot or a sensor has malfunctioned.
Inspect cards adjacent to the one reporting the condition to discover the cause.
● If directly adjacent cards are not normal temperature, suspect a genuine overheating condition.
● If directly adjacent cards are normal temperature, suspect a faulty sensor.
When the system detects a genuine over-temperature condition, it powers off the card. To recognize this condition, look for the
following system messages:
CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high (temperature reaches or
exceeds threshold of
[value]C)
CHMGR-2-TEMP_SHUTDOWN_WARN: WARNING! temperature is [value]C; approaching shutdown
threshold of [value]C
To view the programmed alarm thresholds levels, including the shutdown value, use the show alarms threshold command.
Example of the show alarms threshold Command
DellEMC#show alarms threshold
-- Temperature Limits (deg C) --
----------------------- ---------------------------------------------
Minor Minor Off Major Major Off Shutdown
CpuOnBoard 95 94 100 99 NA
-- Temperature Limits (deg C) --
----------------------- ---------------------------------------------
Minor Minor Off Major Major Off Shutdown
Bcm56960 100 99 105 104 110
-- Temperature Limits (deg C) --
----------------------- ---------------------------------------------
Minor Minor Off Major Major Off Shutdown
Bcm56960 100 99 105 104 110
-- Temperature Limits (deg C) --
----------------------- ---------------------------------------------
Minor Minor Off Major Major Off Shutdown
1088