Release Notes
Table Of Contents
- Dell EMC System S6010–ON 9.14(2.9P1) Release Notes
- Document Revision History
- Supported Hardware
- Supported Software
- New Dell Networking OS Version 9.14(2.9) Features
- Restrictions
- Changes to Default Behavior and CLI Syntax
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Upgrading the ONIE Package for the S6010-ON System
- Upgrading the DIAG Package for the S6010-ON System
- Installing Dell EMC Networking OS on the S6010-ON using ONIE
- Upgrade the S6010-ON Dell EMC Networking OS Image and Boot Code using Dell EMC Networking OS CLI
- Upgrading the CPLD
- Uninstalling Dell EMC Networking OS from the S6010-ON
- Support Resources
upgrade fpga-image stack-unit booted
DellEMC#upgrade fpga-image stack-unit 1 booted
Current information for the system:
========================================================================
Card Device Name Current Version New Version
------------------------------------------------------------------------
Unit1 S6010-ON SYSTEM CPLD 12 12
Unit1 S6010-ON MASTER CPLD 12 12
Unit1 S6010-ON SLAVE CPLD 5 5
***********************************************************************
* Warning - Upgrading FPGA is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Upgrade image for stack-unit 1 [yes/no]: yes
FPGA upgrade in progress!!! Please do NOT power off the unit!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade result :
================
Unit 1 FPGA upgrade successful Unit 1. Please power cycle to take effect.
DellEMC#Dec 15 14:50:41: %S6010-ON:1 %DOWNLOAD-6-FPGA_UPGRADE: stack-unit 1 fpga
upgrade success.
2. Power cycle the system physically. Switch off the system by unplugging the power chords from the REAR PSUs and wait
until the PSU FAN–REAR STATUS LED is completely OFF.
NOTE: Do not switch on the system with PSU–REAR LED glowing AMBER.
You can alternatively power cycle the switch using the power-cycle stack-unit <1-6> command as follows:
DellEMC#power-cycle stack-unit 1
Proceed with power-cycle? Confirm [yes/no]:yes
3. The CPLD version can be verified using show revision command output:
EXEC Privilege Mode
show revision
DellEMC#show revision
-- Stack unit 1 --
S6010-ON SYSTEM CPLD : 12
S6010-ON MASTER CPLD : 12
S6010-ON SLAVE CPLD : 5
Uninstalling Dell EMC Networking OS from the S6010-
ON
To uninstall the Dell EMC Networking OS version 9.14(2.9) from the S6010-ON device, perform the following steps:
20