Upgrading the CPLD
The S6010-ON system with Dell EMC Networking OS Version 9.14(2.9) requires System CPLD revision 12, Master CPLD revision
12, and Slave CPLD revision 5.
Verify that a CPLD upgrade is required
Use the following command to identify the CPLD version:
DellEMC# show revision
-- Stack unit 1 --
S6010-ON SYSTEM CPLD : 12
S6010-ON MASTER CPLD : 12
S6010-ON SLAVE CPLD : 5
Use the following command to view the CPLD version that is associated with the Dell EMC Networking OS image:
Dell#show os-version
RELEASE IMAGE INFORMATION :
---------------------------------------------------------------------
Platform Version Size ReleaseTime
S-Series:S6010 9.14(2.9) 67659844 Dec 15 2020 11:26:55
TARGET IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
runtime 9.14(2.9) Control Processor passed
BOOT IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
boot flash 3.26.2.10 Control Processor passed
BOOTSEL IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
boot selector 3.26.0.0-4
Control Processor passed
FPGA IMAGE INFORMATION :
---------------------------------------------------------------------
Card FPGA Name Version
stack-unit 1 S6010-ON SYSTEM CPLD 12
stack-unit 1 S6010-ON MASTER CPLD 12
stack-unit 1 S6010-ON SLAVE CPLD 5
DellEMC#
Upgrading the CPLD Image
NOTE:
The upgrade fpga-image stack-unit 1 booted command is hidden when using the FPGA Upgrade
feature in the CLI. However, it is a supported command and will be accepted when entered as documented.
NOTE: Ensure that the BIOS version is 3.26.0.0-4. You can verify this version using show system stack-unit 1 command.
To upgrade the CPLD image on S6010-ON, follow these steps.
1. Upgrade the CPLD image.
EXEC Privilege Mode