Release Notes
Table Of Contents
- Dell EMC Networking S3100 Series Release Notes, OS Version 9.14(2.9P1)
- Document Revision History
- Requirements
- New Dell EMC Networking OS Version 9.14(2.9) Features
- Restrictions
- Changes to Default Behavior and CLI Syntax
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Upgrade Instructions
- Support Resources
The Dell EMC Networking OS versions present in A: and B: can be viewed for individual units by specifying the stack unit id
[1–12] in the command or for all the stack units by specifying all in the command.
DellEMC#show boot system stack-unit all
Current system image information in the system:
=========================================================
Type Boot Type A B
---------------------------------------------------------
stack-unit 1 FLASH BOOT 9.14(2.9) 9.14(2.8) [boot]
stack-unit 2 FLASH BOOT 9.14(2.9) 9.14(2.8) [boot]
stack-unit 3 FLASH BOOT 9.14(2.9) 9.14(2.8) [boot]
stack-unit 4 is not present.
stack-unit 5 is not present.
stack-unit 6 is not present.
stack-unit 7 is not present.
stack-unit 8 is not present.
stack-unit 9 is not present.
stack-unit 10 is not present.
stack-unit 11 is not present.
stack-unit 12 is not present.
DellEMC#
6. Change the primary boot parameter to the upgraded partition (A: or B:).
CONFIGURATION mode
boot system stack-unit {1-12 | all} {default | primary | secondary} {flash://file-name |
ftp://file-url | system: {A: | B:} | tftp://file-url }
DellEMC(conf)#boot system stack-unit all primary system: a:
DellEMC(conf)#
7. Save the upgrade configuration so that it is retained after a reload.
EXEC Privilege mode
write memory
DellEMC#write memory
!!!
Dec 10 17:01:33: %STKUNIT2-M:CP %FILEMGR-5-FILESAVED: Copied running-config to
startup-config in flash by default
..Synchronizing data to peer stack-unit
!!!!!!!!!!!!!!!!!!
DellEMC#
8. Reload the switch so that the Dell EMC Networking OS image is retrieved from flash.
EXEC Privilege mode
reload
DellEMC#reload
Proceed with reload [confirm yes/no]: yes...
9. Verify that the switch is upgraded to the latest Dell EMC Networking OS version.
EXEC Privilege mode
show version
DellEMC#show version
Dell EMC Real Time Operating System Software
Dell EMC Operating System Version: 2.0
Dell EMC Application Software Version: 9.14(2.9)
Copyright (c) 2000-2020 by Dell Inc. All Rights Reserved.
Build Time: Thu Dec 10 11:34:10 2020
Build Path: /build/build01/SW/SRC
Dell EMC Networking OS uptime is 1 hour(s), 31 minute(s)
System image file is "system://A"
10