White Papers

Table Of Contents
Stack Unit Board temperature : 46 Degree C
Stack Unit Number : 0
**************************Stack Unit EEPROM INFO**************************
**************MFG INFO*******************
Data in Chassis Eeprom Mfg Info is listed as...
Vendor Id : 07
Country Code : 06
Date Code : 10222012
Serial Number : SWDG129100003
Part Number : 2P7Y5
Product Revision : A
Product Order Number : 02P7Y52BE0005A00123SBC902
**************************** S4820T LEVEL 0 DIAGNOSTICS**************************
diagS4810DumpPowerGoodStatus[653]: ERROR: Psu : 0 Output voltage is NOT in regulation
range
Test 1.000 - Psu Power Good Test .................................... FAIL
Test 1.001 - Psu Power Good Test .................................... PASS
Test 1 - Psu Power Good Test ....................................... FAIL
diagS4820DumpPsuStatus[1753]: ERROR: Psu0: Reporting fault in Current, Voltage and Fan
condition
diagS4820DumpPsuStatus[1757]: ERROR: Psu0: Output voltage is NOT in regulation range
Test 2.000 - Fan Psu Status test .................................... FAIL
Test 2.001 - Fan Psu Status test .................................... PASS
Test 2 - Fan Psu Status Test ....................................... FAIL
Test 3.000 - Fan board presence Test ................................ PASS
Test 3.001 - Fan board presence Test ................................ PASS
Test 3 - Fan Board Presence Test ................................... PASS
Test 4.000 - Board Fan Status Test .................................. PASS
Test 4.001 - Board Fan Status Test .................................. PASS
Test 4.002 - Board Fan Status Test .................................. PASS
Test 4.003 - Board Fan Status Test .................................. PASS
Test 4 - Board Fan Status Test ..................................... PASS
Test 5 - Fan Tray Air Flow Status Test ............................. PASS
Test 6.000 - TMP75A-CPU ............................................. PASS
Test 6.001 - TMP75B-MAC ............................................. PASS
Test 6.002 - TMP75C-LEFT-PHY ........................................ PASS
Test 6.003 - TMP75D-RIGHT-PHY ....................................... PASS
Test 6 - Temp Sensor Access Test .................................... PASS
Test 7 - RTC Presence Test .......................................... PASS
Test 8 - SDRAM Presence Test ........................................ PASS
Trace Logs
In addition to the syslog buffer, Dell EMC Networking OS buffers trace messages which are continuously written by various Dell
EMC Networking OS software tasks to report hardware and software events and status information.
Each trace message provides the date, time, and name of the Dell EMC Networking OS process. All messages are stored in a
ring buffer. You can save the messages to a file either manually or automatically after failover.
Auto Save on Crash or Rollover
Exception information for MASTER or standby units is stored in the flash:/TRACE_LOG_DIR directory. This directory contains
files that save trace information when there has been a task crash or timeout.
On a MASTER unit, you can reach the TRACE_LOG_DIR files by FTP or by using the show file command from the
flash://TRACE_LOG_DIR directory.
On a Standby unit, you can reach the TRACE_LOG_DIR files only by using the show file command from the flash://
TRACE_LOG_DIR directory.
NOTE: Non-management member units do not support this functionality.
Debugging and Diagnostics 1041