Users Guide

Table 104. MIB Objects to Display support for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable
IDPROM user info (continued)
MIB Object OID Description
dellNetIfTransSerialNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.7 Specifies the Serial Number of the Optic
inserted
dellNetIfTransTransmitPowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.8 Specifies Lane 1 Tx power value in dBm
dellNetIfTransTransmitPowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.9 Specifies Lane 2 Tx power value in dBm
dellNetIfTransTransmitPowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.10 Specifies Lane 3 Tx power value in dBm
dellNetIfTransTransmitPowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.11 Specifies Lane 4 Tx power value in dBm
dellNetIfTransReceivePowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.12 Specifies Lane 1 Rx power value in dBm
dellNetIfTransReceivePowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.13 Specifies Lane 2 Rx power value in dBm
dellNetIfTransReceivePowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.14 Specifies Lane 3 Rx power value in dBm
dellNetIfTransReceivePowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.15 Specifies Lane 4 Rx power value in dBm
dellNetIfTransTemperature 1.3.6.1.4.1.6027.3.11.1.3.1.1.16 Specifies Temperature value of the
Optics inserted
SNMP Example Output (Single Interface)
DellEMC$ snmpwalk -v 2c -c public -m all -M 10.16.150.140 .1.3.6.1.4.1.6027.3.11.1.3 |
grep 2112517
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransDeviceName.2112517 = STRING: "stack-
unit-1 port-31"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPort.2112517 = STRING: "Fo 1/31"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsPresent.2112517 = INTEGER: true(1)
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsType.2112517 = STRING: "40GBASE-
LR4"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransVendorName.2112517 = STRING: "FINISAR
CORP."
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPartNumber.2112517 = STRING: "FTL4C1QE1C-
FC"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransSerialNumber.2112517 = STRING: "UNF0FKU"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane1.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane2.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane3.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane4.2112517 = ""
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane1.2112517 = STRING:
"-1.433315" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane2.2112517 = STRING:
"0.051805" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane3.2112517 = STRING:
"-0.270108" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransReceivePowerLane4.2112517 = STRING:
"-0.134970" dBm
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTemperature.2112517 = STRING:
"37.816406" degrees Centigrade
Simple Network Management Protocol (SNMP)
823