Release Notes

Upgrade the CPLD Images
On the S6100ON, you must upgrade the switchcard, CXP, 40G, and 100G CPLD images separately.
NOTE: If your CPLD revisions are higher than the ones shown here, DO NOT make any changes. If you have questions
regarding the CPLD revision, contact Technical Support.
Verify that you need a CPLD upgrade
To identify the CPLD version, use the show revision command.
DellEMC# show revision
-- Stack unit 1 --
S6100-ON SWITCHCARD CPLD : 5
S6100-ON IOM CPLD1 : 5
S6100-ON IOM CPLD2 : 12
S6100-ON IOM CPLD4 : 4
S6100-ON MSS FPGA : 1.1
S6100-ON MSS IAP : 2.4
S6100-ON OOB-FPGA : 1.0
DellEMC#
To view the CPLD version that is associated with the Dell EMC Networking OS image, use the following command:
DellEMC#show os-version
RELEASE IMAGE INFORMATION :
---------------------------------------------------------------------
Platform Version Size ReleaseTime
S-Series:S6100-ON 9.14(2.10) 78345374 May 18 2021 17:15:23
TARGET IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
runtime 9.14(2.10) Control Processor passed
BOOT IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
boot flash 3.25.2.14 Control Processor passed
BOOTSEL IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
boot selector 3.25.0.0-6 Control Processor passed
FPGA IMAGE INFORMATION :
---------------------------------------------------------------------
Card FPGA Name Version
stack-unit 1 S6100-ON SWITCHCARD CPLD 5
stack-unit 1 S6100-ON IOM CPLD1 5
stack-unit 1 S6100-ON IOM CPLD2 12
stack-unit 1 : --- NO IOM CPLD3 FOUND --- 5
stack-unit 1 S6100-ON IOM CPLD4 4
stack-unit 1 S6100-ON MSS FPGA 1.1
stack-unit 1 S6100-ON MSS IAP 2.4
stack-unit 1 S6100-ON OOB-FPGA 1.0
20