Release Notes
Table Of Contents
- Dell S6100–ON System Release Notes, OS Version 9.14(2.10)
- Document Revision History
- Requirements
- New Dell Networking OS Version 9.14(2.10) Features
- Restrictions
- Changes to the Default Behavior and CLI Syntax
- Documentation Corrections
- Deferred Issues
- Fixed Issues
- Known Issues
- Upgrading the ONIE Package for the S6100-ON System
- Upgrading the DIAG Package for the S6100-ON System
- Installing Dell EMC Networking OS on the S6100-ON using ONIE
- Upgrading the S6100-ON Dell EMC Networking OS Image using Dell EMC Networking OS CLI
- Upgrade the Boot Selector and Boot Flash Images from Dell EMC Networking OS
- Upgrade the CPLD Images
- Upgrading the SmartFusion Microcontroller Subsystem — SMF MSS-IAP
- Upgrading the SmartFusion Microcontroller Subsystem — SMF MSS-FPGA
- Upgrading the OOB-FPGA Image
- Uninstalling the Dell EMC Networking OS
- Installing a Third Party Operating System
- Contacting Dell EMC
Requirements
The following requirements apply to the S6100-ON system.
Hardware Requirements
The following lists the Dell S6100-ON system hardware requirements:
● Up to four I/O modules of 8 x 10/25/40/50/100 GbE QSFP28 port
●
Up to four I/O modules of 16 x 10/40 GbE QSFP+ ports
● Up to four I/O modules of 4 x 10/25/40/50/100 GbE QSFP28 ports and 4 x 100 GbE CXP ports
● Up to one hundred twenty-eight 10G ports
● Up to one hundred twenty-eight 25G ports
● Up to sixty-four 40G ports
● Up to sixty-four 50G ports
● Up to thirty-two 100G ports
● One each RJ–45 management and console ports, micro universal serial bus (MicroUSB-B) 2.0 port, and USB type A port
● Two small form-factor pluggable plus (SFP+) 10G ports
● Two AC or DC power supply units (PSUs)
● Four fans with airflow from the I/O side to the power supply unit (PSU) side or from the PSU side to the I/O side (optional
fan subsystem available)
The following lists the individual Dell S6100-ON system hardware components that are available to order:
● Fan with airflow from I/O side to PSU side (red—normal air flow direction)
● Fan with airflow from PSU side to I/O side (blue—reversed air flow direction)
● AC or DC power supply with airflow from I/O side to PSU side
● AC or DC power supply with airflow from PSU side to I/O side
NOTE: Fan modules and power supplies are field replaceable units.
NOTE: All fans and PSUs must have the same airflow direction. If you mix the airflow direction, the switch detects the
discrepancy, issues an alarm, and may autoshutdown to avoid heat damage to components. You must correct the mixed
airflow direction.
Software Requirements
Table 2. Software Requirements
Software Minimum Release Requirement
Dell EMC Networking OS 9.14(2.10)
ONIE 3.25.1.3
DIAG-OS 3.25.4.1
NOTE: For information about non-Dell OS versions, see Dell S6100-Open Networking (ON) System Release Notes.
New Dell Networking OS Version 9.14(2.10) Features
The following features are integrated into the Dell EMC Networking 9.14.2 branch through this release:
None.