Deployment Guide
Memory Size : 3203911680 bytes
Temperature : 0C
Voltage : ok
Serial Number : NA
Part Number : <PART NUMB Rev R>
Vendor Id : NA
Date Code : NA
Country Code : NA
Piece Part ID : <SER:)0
PPID Revision : R>
Service Tag : N/A
Expr Svc Code : 0
Auto Reboot : disabled
Burned In MAC : 00:00:00:00:00:00
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm) Power AvgPower AvgPowerStartTime
--------------------------------------------------------------------------------------
1 1 up AC up 6960 48 31 14/4/2017 17:24
1 2 up AC up 6656 40 26 14/4/2017 17:24
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
--------------------------------------------------
1 1 up up 19275 up 19275
1 2 absent
1 3 up up 19275 up 18904
Speed in RPM
DellEMC>
show tech-support
Display a collection of data from other show commands, necessary for Dell EMC Networking technical support to perform
troubleshooting.
Syntax
show tech-support [stack-unit unit-id | page]
Parameters
stack-unit (OPTIONAL) Enter the keywords stack-unit to view CPU memory usage for the
stack member designated by unit-id.
page (OPTIONAL) Enter the keyword page to view 24 lines of text at a time. Press the
SPACE BAR to view the next 24 lines. Press the ENTER key to view the next line
of text.
When using the pipe command ( | ), enter one of these keywords to filter command
output. For details about filtering commands, refer to CLI Basics.
save Enter the keyword save to save the command output.
flash: Save to local flash drive (flash://filename. A maximum of 20
characters.
Command Modes EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.14(0.0) Updated to display the show revision and show os-version command
outputs.
9.12(1.0) Introduced on the S5048F–ON.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.