Users Guide

If OpenFlow VLANs are configured on the switch, spanning-tree protocols cannot be enabled
simultaneously.
Example (Single
Range)
DellEMC(conf)# int vlan 3
DellEMC(conf-if-vl-3)#
Related
Commands
interface configure a physical interface.
interface loopback configure a loopback interface.
interface null configure a null interface.
interface port-channel configure a port channel group.
show vlan display the current VLAN configuration on the switch.
shutdown disable/enable the VLAN.
tagged add a Layer 2 interface to a VLAN as a tagged interface.
untagged add a Layer 2 interface to a VLAN as an untagged interface.
intf-type cr1 autoneg
Enable Clause 73 autonegotiation on a 25G CR1 interface.
Syntax
intf-type cr1 autoneg
Defaults
Not configured
To disable Clause 73 autonegotiation on a 25G CR1 interface, use the no intf-type cr1 autoneg
command.
Command Modes INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.12(1.0) Introduced on the S5048FON.
9.12(0.0) Introduced on the Z9100ON.
Example
DellEMC(conf-if-tf-1/1)#intf-type cr1 autoneg
DellEMC(conf-if-tf-1/1)#no intf-type cr1 autoneg
intf-type cr2 autoneg
Enable Clause 73 autonegotiation on a 50G CR2 interface.
Syntax
intf-type cr2 autoneg
To disable Clause 73 autonegotiation on a 50G CR2 interface, use the no intf-type cr2 autoneg
command.
Defaults
Not configured
Command Modes
INTERFACE
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.12(1.0) Introduced on the S5048FON.
688 Interfaces