CLI Guide

Table Of Contents
Version Description
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
7.8.1.0 The output of the show environment fan command for the S Series is changed to
display fan speeds instead of showing the fan status as up or down.
Usage
Information
The following example shows the output of the show environment command.
Example (all)
DellEMC#show environment
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed
--------------------------------------
1 1 up up 7620
1 2 up up 7680
1 3 up up 7605
1 4 up up 7635
Speed in RPM
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm) Power AvgPower AvgPowerStartTime
--------------------------------------------------------------------------------------
1 1 up AC up 6960 48 31 14/4/2017 17:24
1 2 up AC up 6656 40 26 14/4/2017 17:24
-- Unit Environment Status --
Unit Status Temp Voltage
------------------------------------
* 1 online 32C ok
* Management Unit
-- Optional Modules Environment Status (deg C) --
Unit Module Temperature
----------------------------------------------------
1 1 36
1 2 38
1 3 36
1 4 37
-- Thermal Sensor Readings (deg C) --
Unit CpuOnBoard Bcm56960_F SysInt Bcm56960_R SwitchOn FP-GE FP-SFP+ Bcm_Int Cpu_Int
---------------------------------------------------------------------------------------
1 32 36 32 38 34 34 31 53 30
DellEMC#
DellEMC#show environment fan
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed
------------------------------------------
1 1 up up 7680
1 2 up up 7710
128
Control and Monitoring