Release Notes
Table Of Contents
- Dell Networking C9010, C1048P, N20xx, and N30xx 9.14(2.10) Release Notes
- Document Revision History
- C9010 Hardware
- C1048P Hardware
- N20xx Hardware
- N30xx Hardware
- New in This Release
- Known Behavior
- Changes to Default Behavior and CLI Syntax
- Restrictions
- Deferred Issues
- Fixed Issues
- Known Issues
- Documentation Errata
- Installation Instructions
- Update Instructions
- Support Resources
EXEC Privilege mode
reload
DellEMC# write memory
!
00:11:17: %SYSTEM:CP %FILEMGR-5-FILESAVED: Copied running-config to startup-config
in flash by default
DellEMC#
DellEMC# reload
Proceed with reload [confirm yes/no]: y
rebooting...
After the C9010 reloads, the switch automatically upgrades all attached port extenders.
May 18 15:25:09: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 1/0
May 18 15:25:09: %RPM0-P:CP %BRM-5-PE_DISCOVERED: PE:f8:b1:56:00:01:44 is detected on
cascade port:TenGigabitEthernet 1/0.
May 18 15:25:09: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Po 258
May 18 15:25:11: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 1/1
May 18 15:25:11: %RPM0-P:CP %DOWNLOAD-6-VERSION_MISMATCH_INFO: Received checkin from
PE 0. Expected version = 9-14(2-9) checkin version = 9-14(2-8)
May 18 15:25:12: %RPM0-P:CP %DOWNLOAD-6-UPGRADE_PROGRESS: PE 0 firmware auto sync is
in progress.
May 18 15:25:13: %RPM0-P:CP %BRM-5-PE_UNIT_DOWN: PE:0 Unit:0 Unit
MAC:ab:cd:ef:00:01:02 is operationally down.
May 18 15:25:14: %RPM0-P:CP %BRM-5-BRM_LOG_PE_UNIT_VALIDATE_ERROR: PE:0 Unit:0 is in
error: SW version incompatible state.
May 18 15:25:15: %RPM0-P:CP %BRM-5-PE_DISCOVERED: PE:f8:b1:56:00:01:78 is detected on
cascade port:TenGigabitEthernet 1/1.
May 18 15:25:15: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Po 259
May 18 15:25:17: %RPM0-P:CP %DOWNLOAD-6-VERSION_MISMATCH_INFO: Received checkin from
PE 1. Expected version = 9-14(2-9) checkin version = 9-14(2-8)
May 18 15:25:17: %RPM0-P:CP %DOWNLOAD-6-UPGRADE_PROGRESS: PE 1 firmware auto sync is
in progress.
May 18 15:25:19: %RPM0-P:CP %BRM-5-PE_UNIT_DOWN: PE:1 Unit:1 Unit
MAC:ab:cb:ef:00:01:03 is operationally down.
May 18 15:25:19: %RPM0-P:CP %BRM-5-BRM_LOG_PE_UNIT_VALIDATE_ERROR: PE:1 Unit:1 is in
error: SW version incompatible state.
May 18 15:30:03: %RPM0-P:CP %DOWNLOAD-6-UPGRADE: PE 0 auto upgrade result - upgrade
success, initiating reset.
May 18 15:30:05: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te
1/0
May 18 15:30:05: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Po
258
May 18 15:30:09: %RPM0-P:CP %DOWNLOAD-6-UPGRADE: PE 1 auto upgrade result - upgrade
success, initiating reset.
May 18 15:30:12: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te
1/1
May 18 15:30:12: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Po
259
8. Verify that the system is upgraded to the latest Dell EMC Networking OS version.
EXEC Privilege mode
show chassis brief
show pe {0–255} system brief
Upgrading the Boot Flash and Boot Selector Images
If your C9010 system is running Dell EMC Networking OS version 9.14(2.10), upgrade RPMs and line cards to boot flash (GRUB)
version 3.3.1.21. and boot selector (BIOS) version 3.3.0.4. Upgrade PEs to boot flash version 3.3.1.9. (The boot selector is not
supported on a PE.)
CAUTION:
If you are configuring the BIOS for a VT100+ terminal emulation package with a 80x24 window size and
serial port settings of 9600,n,8,1, do not use flow control.
11