Install Guide

Table Of Contents
Version Description
9.12(1.0) Introduced on the S5048FON.
9.11(0.0) Introduced the static mode on the S4048ON, S4048T-ON, S6000ON, S6010
ON, S6100ON, and Z9100ON.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S6100ON.
9.10(0.1P10) Introduced on the Z9100ON.
9.8(0.0) Introduced on the S4048ON.
9.7(0.0) Introduced on the S6000-ON.
9.4(0.0) Introduced on the S6000.
Example
DellEMC#show vxlan vxlan-instance 1
Instance : 1
Admin State : enabled
Management IP : 192.168.200.200
Gateway IP : 3.3.3.3
MAX Backoff : 30000
Controller 1 : 192.168.122.6:6632 ssl (connected)
Fail Mode : secure
Port List :
Fo 1/49/1 Tf 1/16 Tf 1/20 Po 2
Related
Commands
vxlan-instance- Enable VXLAN Instance configuration on the platform.
show vxlan vxlan-instance logical network
Displays logical network information related to Network Virtualization Overlay (NVO) Gateway.
Syntax
show vxlan vxlan-instance instance ID logical-network [name name]
Parameters
instance ID
Enter the VXLAN instance ID. The platform supports only the instance ID 1 in the
initial release.
name
name
(OPTIONAL) Enter the keyword name and enter the name of VXLAN logical
network up to a length of maximum 30 characters.
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.12(1.0) Introduced on the S5048FON.
9.11(0.0) Introduced the static mode on the S4048ON, S4048T-ON, S6000ON, S6010
ON, S6100ON, and Z9100ON.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S6100ON.
9.10(0.1P10) Introduced on the Z9100ON.
9.8(0.0) Introduced on the S4048ON.