Install Guide

Table Of Contents
Port-channel 1-2
Port-channel 5
twentyFiveGigE 1/1-1/3,1/5-1/9,1/10-1/19,1/20
twentyFiveGigE 1/1-1/2,1/4-1/5,1/6-1/9,1/15,1/17,1/19,1/21
ICMP packet debugging is on for
twentyFiveGigE 1/1,1/2,1/4,1/6,1/8,1/10,1/12,1/14,1/16
DellEMC#
show environment
View system component status (for example, temperature or voltage).
Syntax
show environment [all | fan | pem | stack-unit unit-id | thermal-sensor ]
Parameters
all Enter the keyword all to view all components.
fan Enter the keyword fan to view information on the fans. The output of this command is chassis-
dependent.
pem Enter the keyword pem to view only information on power entry modules.
stack-unit
unit-id
Enter the keywords stack-unit then the unit-id to display information on a specific stack
member.
thermal-sensor Enter the keywords thermal-sensor to view information on thermal sensors.
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC Networking
OS Command Line Reference Guide.
Version Description
9.12(1.0) Introduced on the S5048FON.
9.11(2.1P1) The CLI has been enhanced to show the power, average power and average power start time.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
7.8.1.0 The output of the show environment fan command for the S Series is changed to display
fan speeds instead of showing the fan status as up or down.
Usage
Information
The following example shows the output of the show environment command.