Connectivity Guide

Table Of Contents
The following example displays VTEP to VNI mapping for a specific remote VTEP.
DellEMC# show vxlan vxlan-instance 1 vtep-vni-map
Remote Vtep IP : 10.10.10.10
VNI profile : Profile1
VNID count : 4
VNID list : 100, 200, 300, 400
Remote Vtep IP : 10.10.10.11
VNI profile : Profile2
VNID count : 3
VNID list : 100, 200, 500
The following example displays VXLAN statistics for a specific port and VLAN combination.
DellEMC# show vxlan statistics interface te 0/0 vlan 2
Statistics for Port : Te 0/0 Vlan : 2
Rx Packets : 0
Rx Bytes : 0
Tx Packets : 0
Tx Bytes : 0
The following example displays VXLAN statistics for the specified VXLAN tunnel.
DellEMC# show vxlan vxlan-instance 1 statistics remote-vtep-ip 1.1.1.1
Statistics for Remote-vtep-ip : 1.1.1.1
Unicast:
Rx Packets : 0
Rx Bytes : 0
Tx Packets : 0
Tx Bytes : 0
Non-Unicast:
Tx Packets : 0
Tx Bytes : 0
Use the following command to clear the remote VTEP and access port statistics.
DellEMC# clear vxlan vxlan-instance 1 statistics
Preserving 802.1 p value across VXLAN tunnels
The 802.1p QoS marking preservation is supported over the VXLAN tunnel. The 802.1p priority is carried over from the VXLAN
tunnel to the remote VTEPVXLAN tunnel endpoint. The packets egress out to the correct queue based on the priority value.
In such a scenario, if there is any congestion in the queue, the system generates a pause. The network port should be a vlan for
priority to be carried by the vxlan outer header.
VXLAN Scenario
VXLAN tunnel stays down even if the remote VTEP IP is reachable through a recursive route. Following section explains the
scenario through an example configuration.
The following illustration depicts the topology in which the VTEPs are connected.
Figure 167. VXLAN Scenario
Virtual Extensible LAN (VXLAN)
1047