Owner's Manual
Setting Up a SAS Cluster 27
Verifying and Upgrading the Firmware
To verify and upgrade the firmware:
1
Discover the direct-attached storage of the host system using the MDSM
software that is installed on the host system.
2
Verify that the firmware for the following storage components is at the
minimum required version:
• RAID controller firmware
•PowerVault MD32
xx
storage system firmware
•PowerVault MD12
xx
expansion enclosure firmware
NOTE: For the minimum firmware version requirements, select the
Dell Validated
Components
link at
dell.com/oracle
.
Installing the SAS HBA Adapter Driver
Install the SAS HBA driver from the PowerVault MD32xx Resource media.
NOTE: Ensure that the version of the SAS HBA driver is the same or newer than the
version listed in the Solution Deliverable List (SDL) that can be found for each
Dell-validated component at
dell.com/oracle
.
For assistance in installing drivers on both nodes of the cluster, see the
documentation that came with the PowerVault MD32xx storage enclosure
and the SAS HBAs.
Installing Host-Based Storage Software
Software Installation
The PowerVault MD32xx Series resource media contains software and drivers.
The root of the media contains a readme.txt file covering changes to the
software, updates, fixes, patches, and other important data applicable to
Windows operating systems. The readme.txt file also specifies requirements
for accessing documentation, information regarding versions of the software
on the media, and system requirements for running the software.