Owner's Manual
SAS Cluster Setup for the Dell PowerVault MD3000 17
Cabling Your SAS Storage System
SAS clusters can only be installed in a direct-attached cluster and are limited
to two nodes only.
To configure your nodes in a direct-attached configuration (see Figure 3-2),
complete the following steps:
1
Connect one SAS cable from a port of the SAS controller of node 1
to the In-0 port of RAID controller 0 in the MD3000 RAID enclosure.
2
Connect one SAS cable from a port of the other SAS controller of node 1
to the In-0 port of RAID controller 1 in the MD3000 RAID enclosure.
3
Connect one SAS cable from a port of the SAS controller of node 2
to the In-1 port of RAID controller 0 in the MD3000 RAID enclosure.
4
Connect one SAS cable from a port of the other SAS controller of node 2
to the In-1 port of RAID controller 1 in the MD3000 RAID enclosure.
PowerVault MD3000
• Two CAT 5e/6 cables connected to a LAN
(one from each storage processor module).
• Two SAS connections to each PowerEdge system
node using a SAS 5/E controller. See "Cabling Your
SAS Storage System" on page 17.
Gigabit Ethernet switch
• One CAT 5e/6 connection to the private Gigabit
NIC on each PowerEdge system.
• One CAT 5e/6 connection to the other Gigabit
Ethernet switch.
Table 3-1. SAS Cluster Hardware Interconnections (continued)
Cluster Component Connections