Owner's Manual

8
Before You Begin
Verify that the following tasks have been completed for your cluster:
All hardware is installed in the rack.
All hardware interconnections are configured.
All virtual disks/LUNs, RAID groups, and storage groups are created
on the storage system.
Storage groups are assigned to the cluster nodes.
CAUTION: Before you perform the procedures in the following sections, ensure that
the system hardware and cable connections are installed correctly.
Cabling Your SAS Storage System
Because SAS clusters can only be installed in a direct-attached cluster, they are
limited to two nodes only.
To configure your nodes in a direct-attached configuration (see
Figure 4
),
complete the following steps:
1
Connect one SAS cable from a port of the SAS controller of node 1 to the In-0
port of RAID controller 0 in the MD3000 RAID enclosure.
2
Connect one SAS cable from a port of the other SAS controller of node 1 to
the In-0 port of RAID controller 1 in the MD3000 RAID enclosure.
3
Connect one SAS cable from a port of the SAS controller of node 2 to the In-1
port of RAID controller 0 in the MD3000 RAID enclosure.
4
Connect one SAS cable from a port of the other SAS controller of node 2 to
the In-1 port of RAID controller 1 in the MD3000 RAID enclosure.
Dell PowerVault MD3000 Two CAT 5e/6 cables connected to a LAN
(one from each storage processor module)
Two SAS connections to each PowerEdge system node
using a SAS 5/E controller. See "Cabling Your SAS
Storage System" on page 8
Gigabit Ethernet switch One Cat 5e/6 connection to the private Gigabit NIC
on each PowerEdge system
One Cat 5e/6 connection to the other Gigabit Ethernet
switch
Table 2. SAS Cluster Hardware Interconnections (continued)
Cluster Component Connections