Owner's Manual
Troubleshooting 19
If the private interconnect is down:
a
Start Linux in single-user mode.
b
Enter the following command:
/etc/init.d/init.crs disable
c
Verify that the node can ping over the private interconnect to
the remaining nodes in the cluster.
d
Enter the following command:
/etc/init.d/init.crs enable
Reboot the system. In some cases, the network has a latency of up to
30 seconds before it can ping the remaining nodes in the cluster after
reboot. If this situation occurs, add the following line to the beginning of
your
/etc/inet.d/init.crs
file and reboot your system:
/bin/sleep 30
.
Database Configuration Assistant (DBCA)
There is no response when you click OK in the DBCA Summary window.
This is a Java Runtime Environment timing issue.
Click OK again. If there is still no response, re-start the DBCA
software installation.
Miscellaneous
You receive dd failure error messages while installing the software
using Dell Deployment CD 1.
This issue occurs when a copy of the Enterprise Linux CD is used. Always use
the original CD.
When burning the CD images (ISOs), use the proper options such as -dao if
using the cdrecord command.