Owner's Manual
38 iSCSI Cluster Setup for EqualLogic Storage Systems
Target: iqn.2001-05.com.equallogic:0-8a0906-
97be59d02-d7ef99976814942e-mdi-fra1
Portal: 10.16.7.100:3260,1
Iface Name: eth0-iface
Iface Name: eth1-iface
iSNS:
No targets found.
STATIC:
No targets found.
11
Login to all targets (volumes) from each interface you created in step 5:
iscsiadm -m node -p group_ip_address --interface
iface_name --login
,
where,
group_ip_address
is the IP address of the EqualLogic storage
group, and
iface_name
is the network interface (as defined in step 5) on
the host that is used for iSCSI traffic.
The following example logs into three volumes from each of the two
ifaces
(
eth0-iface
and
eth1-iface
) on a host.
# iscsiadm -m node -p 10.16.7.100 --interface
eth0-iface --login
Logging in to [iface: eth0-iface, target:
iqn.2001-05.com.equallogic:0-8a0906-90ee59d02-
e26f999767b4942e-mdi-ocr-css-spfile, portal:
10.16.7.100,3260]
Logging in to [iface: eth0-iface, target:
iqn.2001-05.com.equallogic:0-8a0906-95ce59d02-
2e0f999767f4942e-mdi-data2, portal:
10.16.7.100,3260]
Logging in to [iface: eth0-iface, target:
iqn.2001-05.com.equallogic:0-8a0906-93ee59d02-
674f999767d4942e-mdi-data1, portal:
10.16.7.100,3260]
Logging in to [iface: eth0-iface, target:
iqn.2001-05.com.equallogic:0-8a0906-97be59d02-
d7ef99976814942e-mdi-fra1, portal:
10.16.7.100,3260]