Owner's Manual
13
NOTE: If you are using a MD3000i with Oracle Enterprise Linux 5, use the following
instructions:
1. Run the following script to install the multipath drive; do not install the multipath from
the MD3000i MDSM CD:
dell-oracle-deployment/scripts/standard/510-
rpms_scsi_linuxrdac.sh
2. When prompted to install the multipath during the MDSM installation, select "No" and
continue installation.
Table 3. iSCSI Hardware Interconnections
Cluster Component Connections
Each PowerEdge
system node
One CAT 5e/6 cable from public NIC to the local area network
(LAN)
One CAT 5e/6 cable from private Gigabit NIC to Gigabit
Ethernet switch (private network)
One CAT 5e/6 cable from redundant private Gigabit NIC to
redundant Gigabit Ethernet switch (private network)
One CAT 5e/6 cable from iSCSI Gigabit NIC to Gigabit
Ethernet switch (iSCSI network)
For additional information on the MD3000i, see your
PowerVault MD3000i set-up documentation.
Each Dell
PowerVault
MD3000i storage
system
Two CAT 5e/6 cables connected to LAN (one from each storage
processor module) for the management interface
Two CAT 5e/6 cables per storage processor for iSCSI
interconnect
For additional information on the MD3000i, see your
PowerVault MD3000i set-up documentation.
Each Dell
PowerVault
MD1000 storage
expansion
enclosure
(optional)
Additional SAS cable connections as required for the MD1000
expansion enclosures