Owner's Manual
12
Task 3: Verifying and Upgrading the Firmware
• Discover the host server’s direct-attached storage using the Modular Disk
Storage Manager software that is installed on the host server.
• Verify that the firmware for the following storage components is at the
minimum required version. Refer to the Solutions Deliverable List (SDL)
for the firmware version requirements.
• RAID controller firmware
• MD3000 storage system firmware
• MD1000 expansion enclosure firmware
Installing the SAS 5/E Adapter Driver
Follow the documentation that came with the MD3000 and the SAS HBAs to
install drivers on both nodes of the cluster.
NOTE: Confirm that the version of the driver on the MD3000 Resource CD is the same as
that on the Dell Oracle Solutions Deliverables List (SDL).
Post Installation Tasks
After installing the drivers and the software, perform the post installation tasks
listed in the
MD3000 Installation Guide
to create the environment shown in the
Operating System and Hardware Installation, Linux Guide
.
NOTE: Dell Best Practices dictate that you configure the disks for the LUNS in a
RAID 10 configuration.
iSCSI Cluster Setup for PowerVault MD3000i and
MD1000 Expansion Enclosures
This section provides information and procedures for configuring your PowerEdge
Systems and PowerVault MD3000i hardware and software to function in a Oracle
Real Application Cluster environment.
Verify the hardware connections, and the hardware and software configurations,
using the "Supported Configuration" figures contained in the
Dell PowerVault
MD3000i Support Matrix
. This document is available on the following Website:
www.support.dell.com
.