Owner's Manual
44 Deployment Guide
To configure the automatic reboot option, perform the following steps:
1
Ty p e :
omconfig system recovery action=reboot
This command sets the automatic reboot timer to a default setting of 480 seconds—the time delay
before the timer automatically reboots an unresponsive system.
2
To change the timer setting to a different value, type:
omconfig system recovery timer=<seconds>
3
To verify the system reboot timer settings, type:
omreport system recovery
Determining the Private Network Interface
To determine which interface device name is assigned to each network interface, perform the following
steps:
1
Determine which types of NICs are in your system.
Refer to table Table 1-7 to identify which integrated NICs are present in your system. For add-in NICs,
you may have Intel PRO/100 family or PRO/1000 family cards or Broadcom NetXtreme Gigabit cards.
You may have to open your system and view the add-in cards to determine which you have.
Table 1-7. Integrated NICs
System Integrated NICs
PowerEdge 1750 Broadcom NetXtreme Gigabit (2)
PowerEdge 1850 Intel PRO/1000 (2)
PowerEdge 2600 Intel PRO/1000
PowerEdge 2650 Broadcom NetXtreme Gigabit (2)
PowerEdge 2800 Intel PRO/1000 (2)
PowerEdge 2850 Intel PRO/1000 (2)
PowerEdge 4600 Broadcom NetXtreme Gigabit (2)
PowerEdge 6650 Broadcom NetXtreme Gigabit (2)
PowerEdge 6600 Broadcom NetXtreme Gigabit (2)
PowerEdge 6800 Broadcom NetXtreme Gigabit (2)
PowerEdge 6850 Broadcom NetXtreme Gigabit (2)