Reference Guide

Cause A battery sensor in the specified system detected that a battery is in a predictive failure state. The sensor
location, chassis location, previous state, and battery sensor status information is provided.
Event ID 1704
Description
Battery sensor detected a failure value Sensor location: <Location in
chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
Battery sensor status: <status>
Severity Error
Cause A battery sensor in the specified system detected that a battery has failed. The sensor location, chassis
location, previous state, and battery sensor status information is provided.
Event ID 1705
Description
Battery sensor detected a non-recoverable value Sensor location: <Location
in chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
Battery sensor status: <status>
Severity Error
Cause A battery sensor in the specified system could not retrieve a value. The sensor location, chassis location,
previous state, and battery sensor status information is provided.
Event ID 1706
Description
Battery sensor detected absence value Sensor location: <Location in
chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
Battery sensor status: <status>
Severity Critical
Cause and Action Cause: A battery sensor in the specified system detected that a battery is absent. The sensor location,
chassis location, previous state, and battery sensor status information is provided.
Action: Check the battery to confirm the presence
Secure Digital SD Card Device Messages
The SD card device sensors monitor instrumented SD card devices in the system. The messages provide the status and error
information for SD card devices present in a chassis.
Event ID 1750
Description
SD card device sensor has failed Sensor location: <Location in chassis>
50 Server Management Messages