Reference Guide

Table 15. Intrusion Events (continued)
Event Message Severity Cause
The chassis is open while the
power is on.
Critical This event is generated when the
intrusion sensor detects an intrusion
while the system is on.
The chassis is closed while
the power is on.
Information This event is generated when the earlier
intrusion has been corrected while the
power is on.
The chassis is open while the
power is off.
Critical This event is generated when the
intrusion sensor detects an intrusion
while the system is off.
The chassis is closed while
the power is off.
Information This event is generated when the earlier
intrusion has been corrected while the
power is off.
BIOS Generated System Events
The BIOS-generated messages monitor the health and functionality of the chipsets, I/O channels, and other BIOS-related
functions.
Table 16. BIOS Generated System Events
Event Message Severity Cause
System Event I/O channel chk.
Critical This event is generated when a critical
interrupt is generated in the I/O
Channel.
System Event PCI Parity Err.
Critical This event is generated when a parity
error is detected on the PCI bus.
System Event Chipset Err.
Critical This event is generated when a chip
error is detected.
System Event PCI System Err.
Information This event indicates historical data, and
is generated when the system has
crashed and recovered.
System Event PCI Fatal Err.
Critical This error is generated when a fatal error
is detected on the PCI bus.
System Event PCIE Fatal Err.
Critical This error is generated when a fatal error
is detected on the PCIE bus.
POST Err.
Critical This event is generated when an error
occurs during system boot. See the
system documentation for more
information on the error code.
POST fatal error #<number> or
<error description>.
Critical This event is generated when a fatal
error occurs during system boot. For
more information, see POST Code
Errors.
Memory Spared redundancy
lost.
Critical This event is generated when memory
spare is no longer redundant.
Memory Mirrored redundancy
lost.
Critical This event is generated when memory
mirroring is no longer redundant.
Memory RAID redundancy lost.
Critical This event is generated when memory
RAID is no longer redundant.
System Event Log Messages for IPMI Systems 197