Reference Guide

Table 12. Memory Events (continued)
Event Message Severity Cause
Memory spare is redundant.
Information This event is generated when the
memory redundancy mode has change to
spare redundant.
Memory spare redundancy is
lost. Check memory device at
location <DIMM number>.
Critical This event is generated when
redundancy is lost in a sparer-configured
memory configuration.
Memory spare redundancy is
degraded. Check memory device
at location <DIMM number>.
Warning This event is generated when there is a
memory failure in a spare-configured
memory configuration.
Hardware Log Sensor Events
The hardware logs provide hardware status messages to the system management software. On particular systems, the
subsequent hardware messages are not displayed when the log is full. These messages provide status and warning messages
when the logs are full.
Table 13. Hardware Log Sensor Events
Event Message Severity Cause
Log full detected.
Critical This event is generated when the SEL
device detects that only one entry can
be added to the SEL before it is full.
Log cleared.
Information This event is generated when the SEL is
cleared.
Drive Events
The drive event messages monitor the health of the drives in a system. These events are generated when there is a fault in the
drives indicated.
Table 14. Drive Events
Event Message Severity Cause
Drive <Drive #> asserted
fault state.
Critical This event is generated when the
specified drive in the array is faulty.
Drive <Drive #> de-asserted
fault state.
Information This event is generated when the
specified drive recovers from a faulty
condition.
Drive <Drive #> drive
presence was asserted.
Information This event is generated when the drive is
installed.
Drive <Drive #> predictive
failure was asserted.
Warning This event is generated when the drive is
about to fail.
Drive <Drive #> predictive
failure was deasserted.
Information This event is generated when the drive
from earlier predictive failure is
corrected.
Drive <Drive #> hot spare was
asserted.
Warning This event is generated when the drive is
placed in a hot spare.
Drive <Drive #> hot spare was
deasserted.
Information This event is generated when the drive is
taken out of hot spare.
System Event Log Messages for IPMI Systems 195