Reference Guide
BMC Watchdog Events
Enter a short description for your reference topic. This should be one or two sentences that describes the topic content.
Table 11. BMC Watchdog Events
Event Message Severity Cause
BMC OS Watchdog timer
expired.
Information This event is generated when the BMC
watchdog timer expires and no action is
set.
BMC OS Watchdog performed
system reboot.
Critical This event is generated when the BMC
watchdog detects that the system has
crashed (timer expired because no
response was received from Host) and
the action is set to reboot.
BMC OS Watchdog performed
system power off.
Critical This event is generated when the BMC
watchdog detects that the system has
crashed (timer expired because no
response was received from Host) and
the action is set to power off.
BMC OS Watchdog performed
system power cycle.
Critical This event is generated when the BMC
watchdog detects that the system has
crashed (timer expired because no
response was received from Host) and
the action is set to power cycle.
The OS watchdog timer reset
the system.
Critical This event is generated when the BMC
watchdog detects that the system has
crashed (timer expired because no
response was received from Host) and
the action is set to reboot.
The OS watchdog timer powered
cycle the system.
Critical This event is generated when the BMC
watchdog detects that the system has
crashed (timer expired because no
response was received from Host) and
the action is set to power cycle.
The OS watchdog timer powered
off the system.
Critical This event is generated when the BMC
watchdog detects that the system has
crashed (timer expired because no
response was received from Host) and
the action is set to power off.
The OS watchdog timer
expired.
Critical This event is generated when the BMC
watchdog timer expires and no action is
set.
Memory Events
The memory modules can be configured in different ways in particular systems. These messages monitor the status, warning,
and configuration information about the memory modules in the system.
Table 12. Memory Events
Event Message Severity Cause
Memory RAID redundancy
degraded.
Warning This event is generated when there is a
memory failure in a RAID-configured
memory configuration.
System Event Log Messages for IPMI Systems 193