Reference Guide

Action: Replace the controller that has hard SecureBoot mode enabled, and then retry the operation. For
information about replacing a PERC, see the iDRAC User's Guide.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 753
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
None
Event ID 2480
Description
Unable to update the firmware on the controller because the controller key change operation is pending.
Severity Warning
Cause and Action Cause: PERC controller firmware update is blocked because the controller key change is pending.
Perform power cycle operation on the host and retry the firmware update.
Action: Perform a power-cycle operation on the host. For example, to perform power-cycle using IDRAC
RACADM Interface, run the RACADM command: racadm serveraction powercycle.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 753
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
None
Event ID 2482
Description
Multiple namespace is detected on the physical device.
Severity Informational
Cause and Action Cause: Multiple namespaces are detected on the physical disk drive identified in the message.
Action: No response action is required.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 901
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
None
Event ID 2699
Description
Connection to CFM lost! : FluidCache
Severity Error
Cause and Action No action required.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
Storage Management Message Reference 173