Reference Guide
Action: Replace the controller that has hard SecureBoot mode enabled, and then retry the operation. For
information about replacing a PERC, see the iDRAC User's Guide.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 753
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
None
Event ID — 2480
Description
Unable to update the firmware on the controller because the controller key change operation is pending.
Severity Warning
Cause and Action Cause: PERC controller firmware update is blocked because the controller key change is pending.
Perform power cycle operation on the host and retry the firmware update.
Action: Perform a power-cycle operation on the host. For example, to perform power-cycle using IDRAC
RACADM Interface, run the RACADM command: racadm serveraction powercycle.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 753
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
None
Event ID — 2482
Description
Multiple namespace is detected on the physical device.
Severity Informational
Cause and Action Cause: Multiple namespaces are detected on the physical disk drive identified in the message.
Action: No response action is required.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 901
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
None
Event ID — 2699
Description
Connection to CFM lost! : FluidCache
Severity Error
Cause and Action No action required.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
Storage Management Message Reference 173