Reference Guide

SNMP Trap
Numbers
754
Event ID 2318
Description Problems with the battery or the battery charger have been detected. The battery health is poor.
Severity Warning / Non-critical
Cause and Action Cause: The battery or the battery charger is not functioning properly.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2188
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID 2319
Description Single-bit ECC error. The DIMM is degrading.
Severity Warning / Non-critical
Cause and Action Cause: The DIMM is beginning to malfunction.
Action: Replace the DIMM to avoid data loss or data corruption. The DIMM is a part of the controller
battery pack. See your hardware documentation for information on replacing the DIMM or contact
technical support.
Related Alert
Information
Clear Alert Number: 753
Related Alert Number: 2320
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event Id 2320
Description
Single-bit ECC error. The DIMM is critically degraded.
Severity Critical / Failure / Error
Cause and Action Cause: The DIMM is malfunctioning. Data loss or data corruption may be imminent.
Action: Replace the DIMM immediately to avoid data loss or data corruption. The DIMM is a part of the
controller battery pack. See your hardware documentation for information on replacing the DIMM or
contact technical support.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2321
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754