Reference Guide
Cause and Action Cause: The only physical disk available to be assigned as a hot spare is using SAS technology. The physical disks in
the virtual disk are using SATA technology. Because of this difference in technology, the hot spare cannot rebuild
data if one of the physical disks in the virtual disk fails.
Action: Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2210
Description Battery requires reconditioning. Initiate the battery learn cycle.
Severity Warning / Non-critical
Cause and Action Cause: Battery is in warn only mode and requires reconditioning.
Action: Initiate the battery learn cycle.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1153
Event ID — 2211
Description
The physical disk is not supported.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk may not have a supported version of the firmware or the disk may not be supported by
your service provider.
Action: If the disk is supported, update the firmware to a supported version. If the disk is not supported by your
service provider, replace the disk with one that is supported.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2212
Description
The controller battery temperature is above normal.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Storage Management Message Reference 97