Reference Guide
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2364
Description All virtual disks are missing from the controller. This situation was discovered during system start-up.
Severity Warning
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
753
Event ID — 2366
Description
Dedicated spare imported as global due to missing arrays.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2367
Description
Rebuild is not possible because mixing of different media type (SSD/HDD) and bus protocols (SATA/SAS) is not
supported on the same virtual disk.
Severity Warning
Cause and Action Cause: The physical disk is using an incompatible technology.
Action: All physical disks in the virtual disk must use the same technology. You cannot use both SAS and SATA
physical disks in the same virtual disk. Remove the physical disk and insert a new physical disk that uses the
correct technology. If the rebuild does not start automatically after you have inserted a suitable physical disk, then
run the Rebuild task.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2326
Part Number= <Part Number>
Local Response Agent (LRA) Number: 2070
Storage Management Message Reference 141