Reference Guide
Severity Warning
Cause and Action Cause: A physical device may have an error. The %1 indicates a substitution variable. The text for this substitution
variable is generated by the firmware and is displayed with the alert in the alert log. This text can vary depending
on the situation.
Action: Verify the health of attached devices. Review the alert log for significant events. Run the PHY integrity
diagnostic tests. You may need to replace faulty hardware. Make sure that the cables are attached securely. See
the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095, 2129, 2201, 2203, 2270, 2282,
2369
Part Number= <Part Number>
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2347
Description The rebuild failed due to errors on the source physical disk.
Severity Critical / Failure / Error
Cause and Action Hardware RAID: Cause and Action
Cause: You are attempting to rebuild data that resides on a defective disk.
Action: Replace the source disk and restore from backup.
Software RAID:
• Perform a backup with the Verify option.
• If the file backup fails, try to restore the failed file from a previous backup.
• When the backup with the Verify option is complete without any errors, delete the Virtual Disk.
• Recreate a new Virtual Disk with new drives.
• Restore the data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2348
Description
The rebuild failed due to errors on the target physical disk.
Severity Critical / Failure / Error
Cause and Action Cause:You are attempting to rebuild data on a disk that is defective.
Action: Replace the target disk. If a rebuild does not automatically start after replacing the disk, initiate the
Rebuild task. You may need to assign the new disk as a hot spare to initiate the rebuild.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
136 Storage Management Message Reference