Reference Guide
SNMP Trap
Numbers
1001
Event ID — 2326
Description A foreign configuration has been detected.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes. The controller has physical disks that were moved from another
controller. These physical disks contain virtual disks that were created on the other controller. See the Import
Foreign Configuration and Clear Foreign Configuration section in the Server Administrator Storage Management
User’s Guide for more information.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2327
Description
The NVRAM has corrupted data. The controller is reinitializing the NVRAM.
Severity Warning / Non-critical
Cause and Action Cause: The nonvolatile random access memory (NVRAM) is corrupt. This may occur after a power surge, a
battery failure, or for other reasons. The controller is reinitializing the NVRAM. The controller properties reset to
the default settings after the reinitialization is complete.
NOTE: The controller is taking the required corrective action. If this alert is generated often (such
as during each reboot), replace the controller.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2266
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2328
Description
The NVRAM has corrupt data.
Severity Warning / Non-critical
Cause and Action Cause: The NVRAM has corrupt data. The controller is unable to correct the situation.
Action: Replace the controller.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 20601
SNMP Trap
Numbers
753
130 Storage Management Message Reference