Reference Guide
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2304
Description An attempt to hot plug an EMM has been detected. This type of hot plug is not supported.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2211
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2305
Description
The physical disk is too small to be used for a rebuild.
Severity Warning / Non-critical
Cause and Action Cause: The physical disk is too small to rebuild the data.
Action: Remove the physical disk and insert a new physical disk that is the same size or larger than the disk that
is being rebuilt. The new physical disk must also use the same technology (for example, SAS or SATA) as the disk
being rebuilt. If the rebuild does not start automatically after you have inserted a suitable physical disk, then run
the Rebuild task. See the
Server Administrator Storage Management User’s Guide for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2326
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2306
Description
Bad block table is 80% full.
Severity Warning / Non-critical
Cause and Action Cause: The bad block table is used for remapping bad disk blocks. This table fills, as bad disk blocks are remapped.
When the table is full, bad disk blocks can no longer be remapped, and disk errors can no longer be corrected. At
this point, data loss can occur. The bad block table is now 80% full.
Action: Back up your data. Replace the disk generating this alert and restore from back up.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2307
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
124 Storage Management Message Reference