Reference Guide

Severity Warning / Non-critical
Cause and Action Cause: The controller has two connectors that are connected to the same enclosure. The communication path on
one connector has lost connection with the enclosure. The communication path on the other connector is
reporting this loss.
Action: Make sure the cables are attached securely and both enclosure management modules (EMMs) are
healthy. See the Cables Attached Correctly section for more information on checking the cables.
Related Alert
Information
Clear Alert Number: 2284
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2284
Description A redundant path has been restored.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is provided for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2284 is a clear alert for alert 2283.
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
901
Event ID — 2285
Description
A disk media error was corrected during recovery.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID — 2286
Description
A Learn cycle start is pending while the battery charges.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
118 Storage Management Message Reference