Reference Guide

<Additional power supply status information>
If in configuration error state:
Configuration error type:<type of configuration error>
Severity Information
Cause A power supply has been reconnected or replaced. The sensor location, chassis location, previous state, power
supply type, additional power supply status, and conguration error type information are provided.
Event ID — 1353
Description
Power supply detected a warning Sensor Location: <Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Power Supply type: <type of power supply>
<Additional power supply status information>
If in configuration error state:
Configuration error type:<type of configuration error>
Severity Warning
Cause A power supply sensor reading in the specied system exceeded a user-denable warning threshold. The sensor
location, chassis location, previous state, power supply type, additional power supply status, and conguration error
type information are provided.
Event ID — 1354
Description
Power supply detected a failure Sensor Location: <Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Power Supply type: <type of power supply>
<Additional power supply status information>
If in configuration error state:
Configuration error type:<type of configuration error>
Severity Error
Cause A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, power
supply type, additional power supply status, and conguration error type information are provided.
Server Management Messages 45