Reference Guide
<Additional power supply status information>
If in configuration error state:
Configuration error type:<type of configuration error>
Severity Information
Cause A power supply has been reconnected or replaced. The sensor location, chassis location, previous state, power
supply type, additional power supply status, and conguration error type information are provided.
Event ID — 1353
Description
Power supply detected a warning Sensor Location: <Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Power Supply type: <type of power supply>
<Additional power supply status information>
If in configuration error state:
Configuration error type:<type of configuration error>
Severity Warning
Cause A power supply sensor reading in the specied system exceeded a user-denable warning threshold. The sensor
location, chassis location, previous state, power supply type, additional power supply status, and conguration error
type information are provided.
Event ID — 1354
Description
Power supply detected a failure Sensor Location: <Location in chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Power Supply type: <type of power supply>
<Additional power supply status information>
If in configuration error state:
Configuration error type:<type of configuration error>
Severity Error
Cause A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, power
supply type, additional power supply status, and conguration error type information are provided.
Server Management Messages 45