Reference Guide

Event ID — 2703
Description There are not enough journal mirrors available to operate. : FluidCache.
Severity Error
Cause and Action To resolve the issue, you must ensure that there are at least two journal mirrors that are accessible. You must
activate either one or more failed cache devices or use the dc_restore utility to rebuild the node.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1604
Event ID — 2704
Description The cluster ID in the journal does not match the cluster ID in the conguration le. : FluidCache.
Severity Error
Cause and Action Service is required. Contact Technical Support.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1604
Event ID — 2705
Description
The journal could not be read/written. : FluidCache.
Severity Error
Cause and Action Service is required. Contact Technical Support.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1604
206 Storage Management Message Reference