Reference Guide

SNMP Trap
Numbers
904
Event ID — 2309
Description A physical disk is incompatible.
Severity Warning / Non-critical
Cause and Action Cause: You have attempted to replace a disk with another disk that is using an incompatible technology. For
example, you may have replaced one side of a mirror with a SAS disk when the other side of the mirror is using
SATA technology.
Action: See the hardware documentation for information on replacing disks.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2310
Description
A virtual disk is permanently degraded.
Severity Critical / Failure / Error
Cause and Action Cause: A redundant virtual disk has lost redundancy. This may occur when the virtual disk suers the failure of
multiple physical disks. In this case, both the source physical disk and the target disk with redundant data have
failed. A rebuild is not possible because there is no redundancy.
Action: Replace the failed disks and restore from backup.
Related Alert
Information
Clear Alert Number: 1204
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2311
Description
The rmware on the EMMs is not the same version. EMM0 %1 EMM1 %2.
Severity Warning / Non-critical
Cause and Action Cause: The rmware on the EMM modules is not the same version. It is required that both modules have the same
version of the rmware. This alert may be caused if you attempt to insert an EMM module that has a dierent
154 Storage Management Message Reference