Reference Guide
Action: Replace the dual in-line memory module (DIMM). The DIMM is a part of the controller battery pack. See
your hardware documentation for information on replacing the DIMM. You may need to restore data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2061
SNMP Trap
Numbers
754
Event ID — 2290
Description Single-bit ECC error on controller DIMM.
Severity Warning / Non-critical
Cause and Action Cause: An error involving a single bit has been encountered during a read or write operation. The error correction
algorithm has corrected this error.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2291
Description
An enclosure management module (EMM) has been discovered.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Storage Management Message Reference 147