Reference Guide

Action: Add a SAS disk that is large enough to be used as the hot spare and assign it as a hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2207
Description The only hot spare available is a SAS disk. SAS disks cannot replace SATA disks.
Severity Warning / Non-critical
Cause and Action Cause: The only physical disk available to be assigned as a hot spare is using SAS technology. The physical disks in
the virtual disk are using SATA technology. Because of this dierence in technology, the hot spare cannot rebuild
data if one of the physical disks in the virtual disk fails.
Action: Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a hot spare.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2210
Description
Battery requires reconditioning. Initiate the battery learn cycle.
Severity Warning / Non-critical
Cause and Action Cause: Battery is in warn only mode and requires reconditioning.
Action: Initiate the battery learn cycle.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1153