Reference Guide
Event ID — 2198
Description The physical disk is too small to be used for Replace member operation.
Severity Warning
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
903
Event ID — 2199
Description The virtual disk cache policy has changed.
Severity Informational
Cause and Action Cause: User has provided invalid input for the chosen operation.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2200
Description
Replace Member Operation not possible as SAS/SATA is not supported in the same virtual disk.
Severity Warning/ Non-critical
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
903
Event ID — 2201
Description
A global hot spare failed.
Severity Warning/ Non-critical
Cause and Action Cause: The controller is not able to communicate with a disk that is assigned as a dedicated hot spare. The disk
may have been removed. There may also be a bad or loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary, replace the
disk and reassign the hot spare.
94 Storage Management Message Reference