Reference Guide

Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions of
the RAID controller drivers. This alert is for informational purposes.
Action: See the Readme file for driver and firmware requirements. In particular, if Storage Management
experiences performance problems, you should verify that you have the minimum supported versions of the
drivers and firmware installed.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
101
Event ID — 2165
Description The RAID controller firmware and driver validation was not performed. The configuration file cannot be opened.
Severity Warning / Non-critical
Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions of
the RAID controller firmware and drivers. This situation may occur for a variety of reasons. For example, the
installation directory path to the configuration file may not be correct. The configuration file may also have been
removed or renamed.
Action: Reinstall Storage Management
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2166
Description
The RAID controller firmware and driver validation was not performed. The configuration file is out of date, missing
the required information, or not properly formatted to complete the comparison.
Severity Warning / Non-critical
Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required versions of
the RAID controller firmware and drivers. This situation has occurred because a configuration file is out of date,
missing the required information, or not properly formatted to complete the comparison.
Action: Reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2167
Description
The current kernel version and the non-RAID SCSI driver version are older than the minimum required levels. See
readme.txt for a list of validated kernel and driver versions.
Severity Warning / Non-critical
84 Storage Management Message Reference