Reference Guide

Action: Check for problems with the cables. See the online help for more information on checking the cables. You
should also check to see if the enclosure has degraded or failed components. To do so, select the enclosure object
in the tree view and click the Health subtab. The Health subtab displays the status of the enclosure components.
Verify that the controller has supported driver and firmware versions installed and that the EMMs are each
running the same version of supported firmware.
Related Alert
Information
Clear Alert Number: 2162
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID — 2138
Description Enclosure alarm enabled.
Severity OK / Normal / Informational
Cause and Action Cause: A user has enabled the enclosure alarm. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2139
Description
Enclosure alarm disabled.
Severity OK / Normal / Informational
Cause and Action Cause: A user has disabled the enclosure alarm.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2140
Description
Dead disk segments restored.
Severity OK / Normal / Informational
Cause and Action Cause: Disk space that was formerly “dead” or inaccessible to a redundant virtual disk has been restored. This
alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
76 Storage Management Message Reference