Reference Guide

Cause and Action Cause: The controller driver is not a supported version.
Action: Install a supported version of the driver. If you do not have a supported driver version available, you can
check with your support provider for information on how to obtain the most current driver.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2135
Description Array Manager is installed on the system.
NOTE: This is not supported on Server Administrator version 6.0.1.
Severity Warning / Non-critical
Cause and Action Cause: Storage Management has been installed on a system that has an Array Manager installation.
Action: Installing Storage Management and Array Manager on the same system is not a supported configuration.
Uninstall either Storage Management or Array Manager.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050
SNMP Trap
Numbers
103
Event ID — 2136
Description
Virtual disk initialization.
Severity OK / Normal / Informational
Cause and Action Cause: Virtual disk initialization is in progress. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: 2088
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2137
Description
Communication time-out.
Severity Warning / Non-critical
Cause and Action Cause: The controller is unable to communicate with an enclosure. There are several reasons why communication
may be lost. For example, there may be a bad or loose cable. An unusual amount of I/O may also interrupt
communication with the enclosure. In addition, communication loss may be caused by software, hardware, or
firmware problems, bad or failed power supplies, and enclosure shutdown.
When viewed in the alert log, the description for this event displays several variables. These variables are:
controller and enclosure names, type of communication problem, return code, and SCSI status.
Storage Management Message Reference 75