Reference Guide
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2112
Description Enclosure was shut down.
Severity Critical / Failure / Error
Cause and Action Cause: The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable temperature
range.
Action: Check for factors that may cause overheating or excessive cooling. For example, verify that the enclosure
fan is working. You should also check the thermostat settings and examine whether the enclosure is located near
a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot or
too cold. See the enclosure documentation for more diagnostic information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID — 2114
Description
A consistency check on a virtual disk has been paused (suspended).
Severity OK / Normal / Informational
Cause and Action Cause: The check consistency operation on a virtual disk was paused by a user.
Action: To resume the check consistency operation, right-click the virtual disk in the tree view and select
Resume Check Consistency.
Related Alert
Information
Clear Alert Number: 2115
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2115
Description
A consistency check on a virtual disk has been resumed.
Severity OK / Normal / Informational
Cause and Action Cause: The check consistency operation on a virtual disk has resumed processing after being paused by a user.
This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2115 is a clear alert for alert 2114.
Related Alert Number: None
Local Response Agent (LRA) Number: None