Reference Guide

Related Alert Number: 2048, 2049, 2050, 2076, 2079, 2081, 2129, 2346
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2057
Description Virtual disk degraded.
Severity Warning / Non-critical
Cause and Action Cause 1: This alert message occurs when a physical disk included in a redundant virtual disk fails. Because the
virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk
can be rebuilt.
Action 1: Replace the failed drive. Rebuild of the virtual disk starts automatically.
NOTE: If you put the drive in a different slot, you need to assign it as a hot spare for the rebuild to
start automatically.
If you put the drive in a different slot, you need to assign it as a hot spare for the rebuild to start automatically.
Cause 2: A physical disk in the disk group has been removed.
Action 2: If a physical disk was removed from the disk group, either replace the disk or restore the original disk.
You can identify which disk has been removed by locating the disk that has a red “X” for its status. Perform a
rescan after replacing the disk.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048, 2049, 2050, 2076, 2079, 2081, 2123, 2129, 2346
Local Response Agent (LRA) Number: 2080
SNMP Trap
Numbers
1203
Event ID — 2058
Description
Virtual disk check consistency started.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2059
Description
Virtual disk format started.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None