Reference Guide

Cause Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists,
contact your service provider. For information about removing and reinstalling the NVDIMM, see the system
Owner's Manual on the support site.
Event ID — 1428
Description
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, is unable to save the
data during the previous system shutdown operation or power loss.
Severity Critical
Cause Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists,
contact your service provider. For information about removing and reinstalling the NVDIMM, see the system
Owner's Manual on the support site.
Event ID — 1429
Description
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, is unable to restore
the data that was saved in the previous 'save' operation.
Severity Critical
Cause Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists,
contact your service provider. For information about removing and reinstalling the NVDIMM, see the system
Owner's Manual on the support site.
Event ID — 1430
Description
An unsupported Non-Volatile Dual In-line Memory Module (NVDIMM) device is of unsupported configuration and
unable to operate as currently configured.
Severity Critical
Cause
Review the memory configuration and make sure the configuration is as per memory rules defined in the system
Owner's Manual on the support site.
Event ID — 1431
Description
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, is not responding.
Severity Critical
Cause
Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists,
contact your service provider. For information about removing and reinstalling the NVDIMM, see the system
Owner's Manual on the support site.
Event ID — 1432
Description
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot mentioned in log, cannot be
configured to save data during a power loss because of an issue in the NVDIMM.
Severity Critical
Server Management Messages 41