Reference Guide
Event ID — 1007
Description
User initiated host system control action Action requested was: <Action>
Severity Information
Cause User requested a host system control action to reboot, power off, or power cycle the system. Alternatively, the
user had indicated protective measures to be initiated in the event of a thermal shutdown.
Event ID — 1008
Description
Systems Management Data Manager Started
Severity Information
Cause Systems Management Data Manager services were started.
Event ID — 1009
Description
Systems Management Data Manager Stopped
Severity Information
Cause Systems Management Data Manager services were stopped.
Event ID — 1011
Description
RCI table is corrupt
Severity Error
Cause This message is generated when the BIOS Remote Configuration Interface (RCI) table is corrupted or cannot be
read by the systems management software.
Event ID — 1012
Description
IPMI Status Interface: <the IPMI interface being used>, <additional information
if available and applicable >
Severity Information
Cause
This message is generated to indicate the Intelligent Platform Management Interface (IPMI) status of the system.
Additional information, when available, includes Baseboard Management Controller (BMC) not present, BMC not
responding, System Event Log (SEL) not present, and SEL Data Record (SDR) not present.
Event ID — 1013
Description
System Peak Power detected new peak value Peak value (in Watts): <Reading>
Severity Information
Cause The system peak power sensor detected a new peak value in power consumption. The new peak value in Watts is
provided.
Event ID — 1014
Description
System software event: <Description>
Server Management Messages 25