Reference Guide

Event Message Severity Cause
was received from Host) and the action is
set to power off.
The OS watchdog timer expired.
Critical This event is generated when the BMC
watchdog timer expires and no action is set.
Memory Events
The memory modules can be configured in different ways in particular systems. These messages monitor the status, warning, and
configuration information about the memory modules in the system.
Table 12. Memory Events
Event Message Severity Cause
Memory RAID redundancy
degraded.
Warning This event is generated when there is a
memory failure in a RAID-configured
memory configuration.
Memory RAID redundancy lost.
Critical This event is generated when redundancy is
lost in a RAID-configured memory
configuration.
Memory RAID redundancy
regained.
Information This event is generated when the
redundancy lost or degraded earlier is
regained in a RAID-configured memory
configuration.
Memory Mirrored redundancy
degraded.
Warning This event is generated when there is a
memory failure in a mirrored memory
configuration.
Memory Mirrored redundancy
lost.
Critical This event is generated when redundancy is
lost in a mirrored memory configuration.
Memory Mirrored redundancy
regained.
Information This event is generated when the
redundancy lost or degraded earlier is
regained in a mirrored memory
configuration.
Memory Spared redundancy
degraded.
Warning This event is generated when there is a
memory failure in a spared memory
configuration.
Memory Spared redundancy lost.
Critical This event is generated when redundancy is
lost in a spared memory configuration.
Memory Spared redundancy
regained.
Information This event is generated when the
redundancy lost or degraded earlier is
regained in a spared memory configuration.
Memory RAID is redundant.
Information This event is generated when the memory
redundancy mode has change to RAID
redundant.
Memory RAID redundancy is
lost. Check memory device at
location(s) <DIMM number>.
Critical This event is generated when redundancy is
lost in a RAID-configured memory
configuration.
Memory RAID redundancy is
degraded. Check memory device
at location(s) <DIMM number >.
Warning This event is generated when there is a
memory failure in a RAID-configured
memory configuration.
Memory is not redundant.
Information This event is generated when the memory
redundancy mode has change to
nonredundant.
System Event Log Messages for IPMI Systems 185